By default, the official app does not display which OIDs the values it displays correspond to and it is not always straight forward to find the correct OID in the Registry. This page provides a mapping for some of the values.

Screenshots where taken from the official Android App (see RCT Power App on the vendors homepage) version 2.500 from 12 Nov 2020, things may look different in newer versions or in the iOS app. The images have been slightly altered to add annotations for easier referencing.

The setup shown here uses a single RCT Power Storage DC 6.0 with RCT Battery Storage battery and RCT Power Switch which is equipped with an RCT Power Sensor.

Note

There is no guarantee that the information is correct, and it may change anytime without notice.

Main overview

The main overview screen is the first thing the app displays after startup. It's showing a diagram that displays the connected components (solar panels, the inverter, battery, power switch) as well as household power consumption and the grid load. Coloured, dashed lines visualize both what is connected to which device and how much energy is flowing (by speeding up or slowing down the animation as well as changing the colour to visualize generation and consumption).

Tapping one of the icons opens tabular views that go into detail about the selected element, more on that later. The image has been edited to add markers, click to zoom:

RCT Power App (Android) main view, displaying connected components such as solar panels, the inverter, battery as well as some measurements about energy generation / consumption and battery state of charge. Annotations were added to refer to individual components.

Marker

OID

Description

android_description

Device name

g_sync.u_sg_avg[0]

Solar generator A voltage (see Solar generator)

dc_conv.dc_conv_struct[0].p_dc_lp

Solar Generator A power

prim_sm.state

Inverter status (enum) (see Inverter)

power_mng.u_acc_mix_lp

Battery voltage (see Battery)

battery.soc

Battery State of Charge

battery.soc_target

Target State of Charge

g_sync.p_acc_lp

Battery Power (negative for discharge)

g_sync.p_ac_load_sum_lp

Load household - external Power (see Household power)

g_sync.p_ac_grid_sum_lp

Total grid power (see Power grid)

Power Switch / Power Sensor (see Power switch / Power sensor)

Values fuer the second solar generator ("Input B") can be retrieved by changing the number in square brakets from 0 to 1:

  • Voltage A: g_sync.u_sg_avg[0]

  • Voltage B: g_sync.u_sg_avg[1]

Note

The app will cycle between the status and the active events in the (D) position if there are active events, such as over- or undervoltage conditions.

Solar generator

The inverter used here has two inputs for solar generators, which are usually strings of multiple solar cells.

RCT Power App (Android) view of a solar generator (solar string). The tabular view shows a set of values that are explained in the table following this image.

As before, [0] denotes generator A and [1] denotes generator B. Values without a number don't distinguish between solar generators. The "Description" is the text in the left column of the table as displayed by the app.

Description

OID

MPP on input A [V]

dc_conv.dc_conv_struct[0].u_target

MPP search step in input A [V]

dc_conv.dc_conv_struct[0].mpp.mpp_step

Solar generator A power [W]

dc_conv.dc_conv_struct[0].p_dc_lp

Enable rescan for global MPP on solar generator A

dc_conv.dc_conv_struct[0].mpp.enable_scan

Fixed voltage Solar generator A [V]

dc_conv.dc_conv_struct[0].mpp.fixed_voltage

Last global rescan

dc_conv.last_rescan

Last global rescan MPP correction on input A [V]

dc_conv.dc_conv_struct[0].rescan_correction

Forecast correction

bat_mng.struct.k

Battery

RCT Power App (Android) view of the battery. The tabular view shows a set of values that are explained in the table following this image.

The "Description" is the text in the left column of the table as displayed by the app.

Description

OID

Battery type

power_mng.battery_type

Battery power [W]

g_sync.p_acc_lp

SOC (State of charge)

battery.soc

Target SOC

battery.soc_target

SOC target selection

power_mng.soc_strategy

Max. battery charge voltage [V]

power_mng.maximum_charge_voltage

Battery voltage [V]

power_mng.u_acc_mix_lp

Min. battery discharge voltage [V]

power_mng.minimum_discharge_voltage

Max. discharge current [A]

battery.maximum_discharge_current

Battery current [A]

acc_conv.i_acc_lp_fast

Max. charge current [A]

battery.maximum_charge_current

Battery temperature [°C]

battery.temperature

Max. compensation power [W]

p_rec_lim[0]

Max. battery to grid power [W]

p_rec_lim[1]

  • "battery.bat_status" (older versions)

  • "Battery status bitfield" (new)

battery.bat_status

Battery circuit impedance

battery.bat_impedance.impedance_fine

Inverter

RCT Power App (Android) view of the inverter. The tabular view shows a set of values that are explained in the table following this image.

The "Description" is the text in the left column of the table as displayed by the app. Descriptions which display multiple values have the additional values as a list without individual description.

Description

OID 1

Device name

android_description

Serial number

inverter_sn

IP Address

wifi.ip

Network mode

wifi.sockb_protocol

Norm

parameter_file

Control software version

svnversion

DC link voltage [V]

  • g_sync.u_zk_sum_avg (left)

  • g_sync.u_zk_n_avg (middle)

  • g_sync.u_zk_p_avg (right)

Current phase [A]

  • g_sync.i_dr_eff[0] (left)

  • g_sync.i_dr_eff[1] (middle)

  • g_sync.i_dr_eff[1] (right)

cos φ

inv_struct.cosinus_phi

Total insulation resistance [Ohm]

is_struct.Riso

start power [w]

prim_sm.Uzk_pump_grad[0]

Heat sink temperature [°C]

db.temp1

Heat sink (battery actuator) temperature [°C]

db.temp2

Day energy [kWh]

energy.e_ac_day

Month energy [kWh]

energy.e_ac_month

Year energy [kWh]

energy.e_ac_year

Total energy [MWh]

energy.e_ac_total

Household power

RCT Power App (Android) view of the house. The tabular view shows a set of values that are explained in the table following this image.

The "Description" is the text in the left column of the table as displayed by the app. Descriptions which display multiple values have the additional values as a list without individual description.

Description

OID

Load household - external Power[W]

g_sync.p_ac_load_sum_lp

Load household phase [W]

  • g_sync.p_ac_load[0] (left)

  • g_sync.p_ac_load[1] (middle)

  • g_sync.p_ac_load[2] (right)

Digital I/O 1 usage

io_board.io1_usage

Digital I/O 2 usage

io_board.io2_usage

RS485 working mode

modbus.mode

Current sensors detected

i_ac_extern_connected

Current sensors are tuned

cs_struct.is_tuned

Power Sensor current Range [A]

current_sensor_max

Max. compensation power [W]

p_rec_lim[0]

Power switch / Power sensor

RCT Power App (Android) view of the Power Switch / Power Sensor. The tabular view shows a set of values that are explained in the table following this image.

The "Description" is the text in the left column of the table as displayed by the app. Descriptions which display multiple values have the additional values as a list without individual description.

Description

OID

Grid phase voltage [V]

  • rb485.u_l_grid[0] (left)

  • rb485.u_l_grid[1] (middle)

  • rb485.u_l_grid[2] (right)

Grid phase frequency [Hz]

  • rb485.f_grid[0] (left)

  • rb485.f_grid[1] (middle)

  • rb485.f_grid[2] (right)

Power Storage phase frequency [Hz]

  • rb485.f_wr[0] (left)

  • rb485.f_wr[1] (middle)

  • rb485.f_wr[2] (right)

Power Switch software version

rb485.version_main

Power Switch bootloader version

rb485.version_boot

Power grid

RCT Power App (Android) view of the power grid. The tabular view shows a set of values that are explained in the table following this image.

The "Description" is the text in the left column of the table as displayed by the app. Descriptions which display multiple values have the additional values as a list without individual description.

Description

OID

Total grid power [W]

g_sync.p_ac_grid_sum_lp

Grid power phase [W]

  • g_sync.p_ac_sc[0] (left)

  • g_sync.p_ac_sc[1] (middle)

  • g_sync.p_ac_sc[2] (right)

AC voltage phase [V]

  • g_sync.u_l_rms[0] (left)

  • g_sync.u_l_rms[1] (middle)

  • g_sync.u_l_rms[2] (right)

Grid frequency [Hz]

grid_pll[0].f

Phase to phase voltage [V]

  • g_sync.u_ptp_rms[0] (left)

  • g_sync.u_ptp_rms[1] (middle)

  • g_sync.u_ptp_rms[2] (right)

Pac max. [W]

p_rec_lim[2]

Max. grid power [W]

nsm.p_limit